  1 fine tuning fiber photoelectric sensor e3x-nh high-precision sensing with auto- and manual-tuning solves all the problems of conventional models suitable for high-precision positioning using the fine sensitivity adjustment function. manual-tuning allows threshold adjustments while sensing objects are moving. operation conditions can be seen at a glance through the incident level indicators and threshold indicators. auto-tuning feature incorporates an automatic sensitivity compensation function ensuring an optimum margin for changes in sensing objects or ambient environments. offers the longest sensing distance. newly added mark-sensing models (blue led). ordering information amplifier units item general-purpose models t imer-function models mark-sensing models output npn pnp npn pnp npn model e3x-nh11 E3X-NH41 e3x-nh21 e3x-nh51 e3x-nhb11 appearance light source (w ave length) red led (680 nm) blue led (470 mm) power supply voltage 12 to 24 vdc 10%, ripple (p-p) 10% max. current consumption 75 ma max. output control output npn open collector , load current: 50 a pnp open collector , load current: 50 a npn open collector , load current: 50 a pnp open collector , load current: 50 a npn open collector , load current: 50 ma max., id l lt alarm output 50 ma max., residual voltage: 1 v max. 50 ma max., residual voltage: 1 v max. 50 ma max., residual voltage: 1 v max. 50 ma max., residual voltage: 1 v max. , residual voltage: 1 v max. circuit protection output short-circuit, reverse polarity , mutual interference prevention response time 1 ms max. for operation and reset respectively sensitivity setting t eaching method fine sensitivity adjustment automatic or manual fine threshold adjustment (13 levels) t imer function --- off-delay timer set to 40 ms ---
e3x-nh e3x-nh 2 fiber units through-beam/slot sensors indicates models that allow free cutting. models without this mark do not allow free cutting. : e3x-nh  : e3x-nhb  application features appearance sensing distance (mm) * (v alues in parentheses: when using the e39-f1 lens unit) standard object (min. sensing object: opaque) model permis- sible bending radius long distance m4 m4 screw (2,000) 90 (250) 700 1.4-mm dia. (0.06-mm dia.) e32-t11l 25 mm 3 dia. 3-mm dia. 700 90 e32-t12l m3 m3 screw 200 0.9-mm dia. (0.04-mm dia.) e32-t21l 2 dia.; small diameter 2-mm dia. 200 e32-t22l m14; with lens; ideal for explosion-proof applications m4 screw 14,000 2,000 10-mm dia. (0.2-mm dia.) e32-t17l general-pur- pose m4 m4 screw (3,000) 55 (420) 400 1.0-mm dia. (0.04-mm dia.) e32-tc200 25 mm m3; possible to mount the reflective side-view conversion attachment e39-f5 m3 screw 360 55 e32-tc200a m3; for detecting minute sensing objects m3 screw 100 0.5-mm dia. (0.04-mm dia.) e32-tc200e thin fiber 2 dia.; for detecting minute sensing objects 2-mm dia. 100 0.5-mm dia. (0.04-mm dia.) e32-t22 25 mm 1.2 dia.; with sleeve m4 screw 90 mm (40 mm) ( ): e32-tc200b4 1.2 dia. 400 55 1.0-mm dia. (0.04-mm dia.) e32-tc200b e32-tc200b4 0.9 dia.; with sleeve m3 screw 90 mm (40 mm) ( ): e32-tc200f4 0.9 dia. 100 0.5-mm dia. (0.04-mm dia.) e32-tc200f e32-tc200f4 flexible (resists breaking) (r1) possible to bend like electric wires (r1); m4 screw 280 (2,100) 1-mm dia. (0.1-mm dia.) e32-t11r 1 mm m3 screw 60 0.5-mm dia. (0.1-mm dia.) e32-t21r flexible (resists breaking) (r4); ideal for mounting on moving sections (r4) m4 screw 360 50 1.0-mm dia. (0.04-mm dia.) e32-t11 4 mm m3 screw 100 0.5-mm dia. (0.04-mm dia.) e32-t21 side-view long distance; space-saving 3-mm dia. 240 30 1.0-mm dia. (0.08-mm dia.) e32-t14l 25 mm suitable for detecting minute sensing objects 1-mm dia. 90 0.5-mm dia. (0.04-mm dia.) e32-t24 screw-mounting type 1,800 200 4.0-mm dia. (0.08-mm dia.) e32-t14 note: 1. for common specifications of the fiber unit, refer to page 6. 2. the size of standard sensing object is the same as the fiber core diameter (lens diameter for models with lens). 3. the sensing distance of the minimum sensing object indicates the rated sensing distance unless otherwise specified. 4. curled-cord models are also available for through-beam and reflective models. * sensing distance indicates values for white paper .
e3x-nh e3x-nh 3 indicates models that allow free cutting. models without this mark do not allow free cutting. : e3x-nh  : e3x-nhb  applicatio n features appearance sensing distance (mm) *1 (v alues in parentheses: when using the e39-f1 lens unit) standard object (min. sensing object: opaque) model permis- sible bending radius chemical- resistant teflon-covered* 4 ; withstands chemicals and harsh environments (operating ambient temperature: 30  c to 70  c) 5-mm dia. 1,600 220 4.0-mm dia. (0.12-mm dia.) e32-t12f 40 mm t eflon covered* 4 ; side-view; withstands chemicals and harsh environments (operating ambient temperature: 30  c to 70  c) 5-mm dia. 200 3.0-mm dia. (0.12-mm dia.) e32-t14f heat-resis tant resists 150 c* 3 ; fiber sheath material: fluororesin (operating ambient temperature: 40  c to 150  c) m4 screw 400 35 1.5-mm dia. (0.4-mm dia.) e32-t51 35 mm side-view; resists 150 c* 3 ; suitable for detecting minute sensing objects; fiber sheath material: fluororesin (operating ambient temperature: 40  c to 150  c) 2-mm dia. 130 1.0-mm dia. (0.16-mm dia.) e32-t54 resists 300 c* 5 , with spiral tube; high mechanical strength; fiber sheath material: stainless steel (operating ambient temperature: 40  c to 300  c) m4 screw 300 (3,000) 1.0-mm dia. (0.12-mm dia.) e32-t61 25 mm resists 200 c* 5 ; l-shaped; fiber sheath material: stainless steel 700 1.7-mm dia. (0.12-mm dia.) e32-t84s slot suitable for film sheet detection; no optical axis adjustment required; easy to mount 10 4.0-mm dia. (0.16-mm dia.) e32-g14 25 mm narrow vision field suitable for detecting wafers; 3-mm dia. 1,000 1.7-mm dia. (0.08-mm dia.) e32-t22s 10 mm side-view; suitable for detecting wafers; 3.5 x 3 mm dia. 700 2-mm dia. (0.04-mm dia.) e32-t24s area sensing through-b eam multi-point sensing (4-head) m3 screw 300 2.0-mm dia. (0.04-mm dia.) e32-m21 25 mm stable for detecting minute sensing objects in a wide area; degree of protection: iec60529 ip50 600 (0.4-mm dia.)* 6 e32-t16p 10 mm suitable for detecting over a 10-mm area; long distance 10 mm 1,500 700 (2.0-mm dia.)* 6 e32-t16 25 mm note: 1. for common specifications of the fiber unit, refer to page 6. 2. the size of standard sensing object is the same as the fiber core diameter (lens diameter for models with lens). 3. the sensing distance of the minimum sensing object indicates the rated sensing distance unless otherwise specified. * 1 sensing distance indicates values for white paper . * 2 for continuous operation, use the products within the temperature ranging from 40  c to 130  c. * 3 t eflon is a registered trademark of the dupont company and the mitsui dupont chemical company for their fluoride resin. * 4 indicates the heat-resistant temperature at the fiber tip. for further details, refer to page 26. * 5 indicates values for the sensing distance of 100 mm.
e3x-nh e3x-nh 4 reflective sensors indicates models that allow free cutting. models without this mark do not allow free cutting. : e3x-nh  : e3x-nhb  application features appearance sensing distance (mm) * min. sensing object (copper strand) model permis- sible bending radius long distance m6 m6 screw 200 26 0.012-mm dia. e32-d11l 25 mm 3 dia.; small diameter 3-mm dia. 120 16 e32-d12 m4 m4 screw 50 e32-d21l 3 dia.; small diameter 3-mm dia. 50 e32-d22l general-pur- pose m6 m6 screw 150 20 0.012-mm dia. e32-dc200 25 mm m3; small diameter m3 screw 36 e32-dc200e thin fiber 2.5 dia.; with sleeve m6 screw ( ): e32-dc200b4 90 mm (40 mm) 2.5 dia. 150 20 0.012-mm dia. e32-dc200b e32-dc200b4 25 mm 1.2 dia.; with sleeve m3 screw ( ): e32-dc200f4 90 mm (40 mm) 1.2 dia. 36 e32-dc200f e32-dc200f4 minute object sensing (0.8 mm dia.) 3-mm dia. 0.8-mm dia. 10 e32-d33 flexible (r1) possible to bend like electric wires (r1); m6 screw 90 0.02-mm dia. e32-d11r 1 mm m3 screw 14 e32-d21r flexible (resists breaking) (r4) ideal for mounting on moving sections (r4) m6 screw 90 12 0.012-mm dia. e32-d11 4 mm m3 screw 14 e32-d21 coaxial reflective m6 coaxial; positioning accuracy m6 screw 150 20 0.012-mm dia. e32-cc200 25 mm 3-dia. coaxial; positioning accuracy 3-mm dia. 80 10 e32-d32l 2-dia. coaxial; high-precision positioning possible; possible to mount small-spot (0.5-mm dia) lens (e39-f3a) 2-mm dia. 40 e32-d32 note: 1. for common specifications of the fiber unit, refer to page 6. 2. the size of standard sensing object is the same as the fiber core diameter (lens diameter for models with lens). 3. the sensing distance of the minimum sensing object indicates the rated sensing distance unless otherwise specified. in case of the reflective fiber units, however , the sensing distance indicates the distance where the smallest object can be sensed. * sensing distance indicates values for white paper .
e3x-nh e3x-nh 5 indicates models that allow free cutting. models without this mark do not allow free cutting. : e3x-nh  : e3x-nhb  application features appearance sensing distance (mm) *1 min. sensing object model permis- sible bending radius side-view reflective 6 dia.; long distance 6-mm dia. 40 0.015-mm dia. e32-d14l 25 mm 2 dia.; small diameter space-saving 2-mm dia. 15 0.012-mm dia. e32-d24 heat-resisting reflective teflon-covered* 3 ; withstands chemicals and harsh environ - ments (operating ambient temperature: 30  c to 70  c) 6-mm dia. 50 10 0.012-mm dia. e32-d12f 40 mm resists 150 c* 2 ; fiber sheath material: fluororesin (operating ambient temperature: 40  c to 150  c) m6 screw 120 12 e32-d51 35 mm resists 300 c* 4 ; fiber sheath material: stainless steel (operating ambient temperature: 40  c to 300  c) m6 screw 45 e32-d61 25 mm resists 400 c* 4 ; fiber sheath material: stainless steel (operating ambient tempera - ture: 40  c to 400  c) m4 screw 1.25-mm dia. 30 e32-d73 retroreflective t ransparent object detection m6 screw reflector e39-r3 10 to 250 0.3-mm dia. e32-r21 +e39-r3 25 mm t ransparent object detection (operating ambient tempera - ture: 25  c to 55  c); degree of protection: iec60529 ip66 reflector e39-r1 150 to 1,500 0.5-mm dia. e32-r16 +e39-r1 limited reflective detects wafers and small differences in height; (operating ambient temperature: 40  c to 105  c); de g ree of p rotection: iec60529 7.2 0.8 0.012-mm dia. e32-l25l 10 mm degree of protection: iec60529 ip50 4 2 e32-l24l detects wafers and small differences in height; de g ree of p rotection: iec60529 3.3 e32-l25 25 mm degree of protection: iec60529 ip50 3.3 e32-l25a fluid-level detection fluid contact type: unbendable section l 150 mm, 350 mm (two types) pure water at 25  c e32-d82f1 e32-d82f2 40 mm t ube-mounting type fluid e32-l25t 10 mm note: 1. for common specifications of the fiber unit, refer to page 6. 2. the size of standard sensing object is the same as the fiber core diameter (lens diameter for models with lens). 3. the sensing distance of the minimum sensing object indicates the rated sensing distance unless otherwise specified. in case of the reflective fiber units, however , the sensing distance indicates the distance where the smallest object can be sensed. * 1 sensing distance indicates values for white paper . * 2 for continous operation, use the products within the temperature ranging from 40 c to 130 c. * 3 t eflon is a registered trademark of the dupont company and the mitsui dupont chemical company for their fluoride resin. * 4 indicates the heat-resistant temperature at the fiber tip. for further details, refer to page 26.
e3x-nh e3x-nh 6 specifications item general-purpose models t imer-function models mark-sens-ing models output npn pnp npn pnp npn model e3x-nh11 E3X-NH41 e3x-nh21 e3x-nh51 e3x-nhb11 indicator operation indicator (orange led), 8-level incident level indicator (green led), 13-level threshold indicator (red led) ambient illumination incandescent lamp: 3,000 x max.; sunlight: 10,000 x max. ambient temperature operating:25 c to 55 c (with no icing) storage: 40 c to 70 c (with no icing) ambient humidity operating: 35% to 85% (with no condensation) insulation resistance 20 m w min. (at 500 vdc) dielectric strength 1,000 v ac at 50/60 hz for 1 minute v ibration resistance 10 to 55 hz, 1.5-mm double amplitude or 300 m/s 2 (approx. 30g) for 2 hrs each in x, y , and z directions shock resistance 500 m/s 2 (approx. 50g) for 3 times each in x, y , and z directions degree of protection iec60529 ip50 connection method prewired (standard cord length: 2 m) w eight (packed state) approx. 100 g material case: pbt ; cover: polycarbonate accessory mounting brackets fiber sheath materials e32-t11r, -t21r, -t22s, -t24s, -d1 1r, -d21r copolymer vinyl chloride e32-t1 1, -t21, -t16p , -d1 1, -d21 v inyl chloride e32-l25l, -l24l reinforced polyethylene other than the above black polyethylene specifications of models other than those in the left table operating ambient temperature 40 c to 70 c operating ambient humidity 35% to 85% (with no icing) differential travel (reflective models) 20% max. of sensing distance degree of protection iec 60529 ip67
e3x-nh e3x-nh 7 attachments name long distance lens unit applications increasing sensing distance model e39-f1 appearance through-beam (separate) applicable fibers e32-t11l e32-tc200 e32-t61 e32-t11r e32-t11 with e3x nh11/41 sensing distance 2,000 mm 3,000 mm 2,100 mm 2,000 mm e3x-nh11/41 standard object opaque objects: 4-mm dia. min. directivity 5 to 40 differential travel --- ambient temperature e32-t61: 40 c to 200 c (do not exceed the operating temperature of the fiber . ) material shaft brass ae a lens optical glass base --- reflector --- name side-view unit applications changing the sensing direction at 90 model e39-f2 appearance through-beam (separate) applicable fibers e32-t11l e32-tc200 e32-t11r e32-t61/11 with e3x nh11/41 sensing distance 400 mm 500 mm 350 mm 400 mm e3x-nh11/41 standard object opaque objects: 3-mm dia. min. directivity 20 to 60 differential travel --- ambient temperature e32-t61: 40 c to 200 c (do not exceed the operating temperature of the fiber .) material shaft brass ae a lens optical glass base --- reflector ---
e3x-nh e3x-nh 8 name lens-equipped reflective unit small spot lens unit applications converting through-beam sensors to reflective sensors detection over 0.5-mm-dia. spots model e39-f3 e39-f3a appearance reflective reflective applicable fibers e32-t11l e32-tc200 e32-t61 e32-t11r e32-t11 e32-d32 with e3x-nh11/41 sensing distance (standard object) white paper 10 to 300 mm* 1 (20 x 20 cm) 35 to 180 mm* 1 (20 x 20 cm) 25 to 120 mm (20 x 20 cm) 35 to 180 mm* 1 (20 x 20 cm) 20 mm j) black paper --- 5 to 120 mm* 1 (200 x 200 cm) 5 to 80 mm* 1 (200 x 200 cm) 25 to 120 mm 5 to 70 mm* 1 (200 x 200 cm) white paper 25 x 25 mm directivity --- --- differential travel 20% of sensing distance 20% of sensing distance ambient temperature e32-t61: 40 c to 200 c (do not exceed the operating temperature of the fiber.) operating: 40 c to 70 c material shaft brass aluminum ae a lens optical glass optical glass base aluminum --- reflector --- --- * 1 these values are possible when the angle of the e39-f3 is small - est (parallel). name side-view reflective unit applications converting through-beam to reflective sensor model e39-f5 appearance reflective applicable fibers e32-tc200a with e3x- nh11/41 sensing distance (t d d white paper 60 mm (10 x 10 cm) nh11/41 (standard object) black paper 5 to 20 mm (10 x 10 cm) directivity --- differential travel 20% of sensing distance ambient temperature operating: 40 c to 70 c material shaft --- ae a lens --- base brass reflector stainless beam spot characteristics e39-f3a with e32-d32 insertion distance (mm) focal length d (mm) fiber e32-d32 : insertion d: focal distance d  : spot diameter (mm) 1.0 0.8 0.5
e3x-nh e3x-nh 9 spiral tubes model e39-f32a5 e39-f32a e39-f32b5 e39-f32b e39-f32c5 e39-f32c e39-f32d5 e39-f32d appearance end cap tube head connector c length (l) 500 mm 1,000 mm 500 mm 1,000 mm 500 mm 1,000 mm 500 mm 1,000 mm head outer diameter (a) 6 dia. 7 dia. 8.5 dia. head inner diameter (b) m3 x 0.5, depth: 4 m4 x 0.7, depth: 4 m6 x 0.75, depth: 4 t ube outer diameter (c) 4.6 dia. 5.6 dia. 7 dia. applicable fiber e32-dc200e e32-dc200f(4) e32-d21 e32-tc200e e32-tc200f(4) e32-t21 e32-t21l e32-tc200 e32-tc200b(4) e32-t11 e32-t51 e32-t11l e32-dc200 e32-dc200b(4) e32-cc200 e32-d11 e32-d51 e32-d11l ambient temperature operating: 40 c to 150 c (do not exceed the operating temperature of the fiber) ambient humidity operating: 35% to 85% permissible bending radius 30 mm min. t ensile strength between head connector and end cap with tube: 1.5 n m (15 kgf cm ) t ube: 2 n m (20 kgf cm) compression load t ube: 29.4 n (3 kgf) accessories name fiber cutter fine-fiber attachment fiber connector sleeve bender model e39-f4 e39-f9 e39-f10 e39-f11 appearance 3.6 dia. 3 dia. 3.8 dia. features used to cut fibers to desired lengths used when inserting fine fibers into the amp used to connect additional fibers for extension used to bend fiber sleeves applicable fiber all models equipped with fibers that can be trimmed. e32-dc200e, -tc200e e32-dc200f(4), -tc200f(4) e32-d21, -d21l, -d22l e32-t21, -t21l, -t22l e32-d32, -t22 e32-d24. -t24 e32-d33 e32-r21, e32-d21r e32-dc200, -tc200 e32-dc200b(4), -tc200b(4) e32-tc200a e32-t14, -g14 e32-d1 1l, -t1 1l, -t12l e32-d14l, -t14l e32-t17l e32-tc200b(4) e32-dc200f(4), -tc200f(4) e32-dc9g(4) provided with fiber units sold separately
e3x-nh e3x-nh 10 engineering data excess gain ratio (typical) with standard sensing object. ? e3x-nh  1 sensing distance sensing object e32-tc200 e32-tc200 with e39-f1 e32-t11l e32-t11l with e39-f1 e32-t11l with e39-f2 e32-t11l with e39-f3 e32-t21l e32-t17l excess gain ratio sensing distance (mm) excess gain ratio sensing distance (m) excess gain ratio sensing distance (mm) excess gain ratio excess gain ratio excess gain ratio sensing distance (m) sensing distance (mm) sensing distance (mm) excess gain ratio excess gain ratio sensing distance (mm) sensing distance (m) sensing distance sensing distance sensing distance sensing distance sensing distance sensing distance sensing distance e32-t16 excess gain ratio sensing distance (m) sensing distance e32-t11r e32-t21r e32-t14l excess gain ratio sensing distance (mm) sensing distance e32-t22s e32-t24s excess gain ratio sensing distance (mm) sensing distance (mm) sensing distance sensing distance e32-t84s e32-t54 sensing distance (mm) sensing distance sensing distance (mm) sensing distance excess gain ratio excess gain ratio excess gain ratio e32-t14f e32-dc200 e32-d11l e32-d21l excess gain ratio sensing distance (mm) excess gain ratio sensing distance (mm) excess gain ratio sensing distance (mm) sensing distance sensing distance sensing object sensing distance sensing object sens- ing ob- ject excess gain ratio sensing distance (mm) sensing distance sensing distance excess gain ratio sensing distance (mm) excess gain ratio sensing distance (mm) sensing distance
e3x-nh e3x-nh 11 excess gain ratio (typical) with standard sensing object e32-d11r e32-d21r excess gain ratio sensing distance (mm) excess gain ratio sensing distance (mm) sensing distance sensing distance sensing object sensing object ? e3x-nhb11 e32-tc200 e32-tc200 + e39-f1 e32-d11 e32-d12 excess gain ratio set distance (mm) excess gain ratio set distance (mm) excess gain ratio set distance (mm) excess gain ratio set distance (mm) sensing distance sensing distance sensing distance sensing distance operating range (typical) with standard sensing object at max. sensitivity . ? e3x-nh  1 e32-t11l w i th e39-f3 e32-d c 200 e32-d11l e32-d12 e32-d21l e32-dc200e operating position y (mm) operating position y (mm) operating position y (mm) operating position y (mm) operating position y (mm) operating position y (mm) sensing object sensing object operating position y (mm) sensing object sensing object sensing object set distance x (mm) sensing object set distance x (mm) sensing object set distance x (mm) set distance x (mm) set distance x (mm) e32-d21 set distance x (mm) set distance x (mm) e32-d11r e32-d32 operating position y (mm) sensing object set distance x (mm) e32-cc200 operating position y (mm) operating position y (mm) sensing object sensing object set distance x (mm) set distance x (mm) e32-d11 e32-d21r operating position y (mm) sensing object set dis- tance x (mm) operating position y (mm) set dis- tance x (mm)
e3x-nh e3x-nh 12 operating range (typical) with standard sensing object at max. sensitivity . e32-d32l e32-d33 e32-d51 e32-l25l operating position y (mm) sensing object operating position y (mm) sensing object operating position y (mm) operating position y (mm) set distance x sensing object set dis- tance x operating position y set distance x (mm) set distance x (mm) sensing object set distance x (mm) set distance x (mm) sensing object ? e3x-nhb11 e32-dc200 e32-d11l e32-cc200 e32-d51 set distance x (mm) set distance x (mm) set distance x (mm) set distance x (mm) operating position y (mm) operating position y (mm) operating position y (mm) operating position y (mm) parallel operating range (typical) at max. sensitivity. ? e3x-nh  1 e32-tc200 e32-tc200 with e39-f2 e32-t11l e32-t11l with e39-f1 e32-t11l with e39-f2 e32-t21l e32-t22 parallel operating range y (mm) parallel operating range y (mm) set distance x (mm) set distance x (mm) set distance x (mm) set distance x (m) set distance x (mm) set distance x (mm) set distance x (mm) e32-t11r parallel operating range y (mm) parallel operating range y (mm) parallel operating range y (mm) parallel operating range y (mm) parallel operating range y (mm) parallel operating range y (mm) set distance x (m)
e3x-nh e3x-nh 13 parallel operating range (typical) at max. sensitivity. e32-t11 e32-t21 parallel operating range y (mm) parallel operating range y (mm) set distance x (mm) set distance x (mm) e32-t14l parallel operating range y (mm) set distance x (mm) e32-t21r parallel operating range y (mm) e32-t17l e32-t12f e32-m21 e32-t51 e32-t61 e32-t22s parallel operating range y (mm) parallel operating range y (mm) parallel operating range y (mm) parallel operating range y (mm) set distance x (m) set distance x (m) set distance x (mm) set distance x (mm) set distance x (mm) set distance x (mm) e32-t24s e32-t54 e32-t14f parallel operating range y (mm) parallel operating range y (mm) parallel operating range y (mm) set distance x (mm) set distance x (mm) set distance x (mm) parallel operating range y (cm) e32-t24 e32-t14 set distance x (mm) set distance x (mm) parallel operating range y (mm) parallel operating range y (mm) parallel operating range y (mm) set distance x (mm) e32-t84s set distance x (mm) operating position y (mm) ? e3x-nhb11 e32-tc200 e32-tc200 + e39-f1 set distance x (mm) parallel operating range y (mm) parallel operating range y (mm) set distance x (mm)
e3x-nh e3x-nh 14 nomenclature e3x-nh11 (npn) e3x-nh21 (npn) e3x-nhb11 (npn) note: used for making fine-sensitivity adjustments. operation indicator (orange) on when output is on. incident level indicators (green, 8 levels) on depending on the incident light amount. mode selector switchable among teach, adj, and run modes. up/down selector (see note) select up for increasing the threshold value. select down for decreasing the threshold value. operation mode selector switchable between light-on and dark-on modes. set button for teaching or for fine threshold adjustment threshold indicators (red, 13 levels) indicates threshold level. E3X-NH41 (pnp) e3x-nh51 (pnp)
e3x-nh e3x-nh 15 operation output circuits output model mode selector state of output transistor output circuit t iming chart npn e3x-nh11 e3x-nhb11 light on (l/on) light on brown black orange blue alarm output control output load load operation indicator (orange) 8-level in- cident level indi- cators (green) 13-level threshold indicators (red) 12 to 24 vdc photo- electric sensor main circuit on off on off light received light not received operation indicator (orange) output transistor load (relay) operate release (between brown and black) dark on (d/on) dark on on off on off light received light not received operation indicator (orange) output transistor load (relay) operate release (between brown and black) e3x-nh21 light on (l/on) light on brown black orange blue alarm output control output load load operation indicator (orange) 8-level in- cident level indi- cators (green) 13-level threshold indicators (red) 12 to 24 vdc photo- electric sensor main circuit on off on off light received light not received operation indicator (orange) output transistor load (relay) operate release t : off-delay timer set to 40 ms dark on (d/on) dark on blue on off on off light received light not received operation indicator (orange) output transistor load (relay) operate release t : off-delay timer set to 40 ms pnp E3X-NH41 light on (l/on) light on load load brown black orange blue control output alarm output 12 to 24 vdc operation indicator (orange) 8-level in- cident level indi- cators (green) 13-level threshold indicators (red) photo- electric sensor main circuit on off on off light received light not received operation indicator (orange) output transistor load (relay) operate release (between blue and black) dark on (d/on) dark on blue on off on off light received light not received operation indicator (orange) output transistor load (relay) operate release (between blue and black) e3x-nh51 light on (l/on) light on load brown black control output alarm output 12 to 24 vdc operation indicator (orange) 8-level in- cident level indi- cators (green) 13-level threshold indicators (red) photo- electric sensor main circuit on off on off light received light not received operation indicator (orange) output transistor load (relay) operate release t : off-delay timer set to 40 ms dark on (d/on) dark on load orange blue c i rcu it on off on off light received light not received operation indicator (orange) output transistor load (relay) operate release t : off-delay timer set to 40 ms
e3x-nh e3x-nh 16 sensitivity setting and adjustment refer to the following to select the most suitable sensitivity setting method. it is recommended that with/without-object teaching a nd manual- tuning be tried first. using the sensor at the maximum sensitivity application examples detection of passing objects with through-beam sensor. detection of the existence of objects that interrupt light perfectly . detection of objects with no back- ground objects. checking ic tray arrangements e3x-nh sensing slight differences application examples detection of slight dif ferences in reflec - tion. detection of translucent objects. detection of object surface irregulari- ties. color discrimination. detecting ic chips on film sheet e3x-nh e32-t16p sensitivity setting without objects application examples detection of minute passing objects. detection of lead wires. high-precision positioning. detecting lead frame position e32-d32 lead frame fine-tuning on production lines occasion marginal sensitivity adjustment is required considering the differences of objects. high-precision positioning of electronic parts is required. detecting lead frame rises e3x-nh ideal operation under frequently changing environments occasion dust sticking to the fiber head. sensing objects are slightly dif ferent to one another in color or surface conditions. detecting passing chip parts e3x-nh e32-t16p b. auto-tuning (automatic sensitivity compensation) fine-tuning, if required. e32-t24 detecting cassette t ape cases ensuring reliable detection without being influenced by the dif ference in color or mark. e3x-nh e32-l25a 3.3 mm counting number of pills sensitivity setting film sheet sensitivity adjustment (fine-tuning) 1. maximum sensitivity setting 3. positioning/no-object t eaching 2. w ith/w ithout-object t eaching a. manual-tuning (fine sensitivity adjustment)
e3x-nh e3x-nh 17 sensitivity setting (teaching) note: the sensitivity of the e3x-nh/nhb is factory-set to maximum. when resetting the sensitivity of the e3x-nh to maximum after with/ without-object teaching or positioning/no-object teaching, follow the steps described below . 1. maximum sensitivity setting 1. set the mode selector to teach. press the set button for three seconds minimum. be sure that all the threshold indicators (red) are on. the built-in buzzer beeps once when the threshold indicators are on. press for 3 s min. 2. the sensitivity will be set when the built-in buzzer beeps continuously and all the incident level indicators (green) are on. 3. set the mode selector to run. be sure that only the bottom threshold indicator is on. 2. with/without-object teaching 1. set the mode selector to teach. locate the sensing object in the sensing area and press the set button once. be sure that all the threshold indicators (red) are on. the built-in buzzer beeps once when the threshold indicators are on. press once for 0.5 to 2.5 s through-beam model reflective model reflective model light is in- terrupted. mark base 2. move the object and press the set button. if teaching is ok: all the incident level indicators (green) are on. the built-in buzzer beeps once. press once for 0.5 to 2.5 s
e3x-nh e3x-nh 18 if teaching is ng: the threshold indicator (red) flashes. the built-in buzzer beeps 3 times. change the position of the object and the sensing distance that have been set and repeat from the beginning. through-beam model reflective model reflective model light is received. mark base press again once for 0.5 to 2.5 s 3. set the mode selector to run. be sure that the middle threshold indicator is on, which means the threshold will be set to the middle between the values obtained with and without the sensing object. 3. positioning/no-object teaching 1. set the mode selector to teach. press the set button once without a sensing object in the sensing area. be sure that all the threshold indicators (red) are on. the built-in buzzer beeps once when the threshold indicators are on. press once for 0.5 to 2.5 s 2. set the mode selector to run. the threshold is set automatically. use the manual tuning function for making fine adjustments.
e3x-nh e3x-nh 19 sensitivity adjustment (tuning) a. manual-tuning (fine sensitivity adjustment) note: the auto-tuning function will be disabled if manual-tuning is executed. 1. after setting the sensitivity of the e3x-nh, select the adjustment direction with the up/down selector in the adj mode. (1) (2) 2. press the set button in adj mode. be sure that the threshold changes whenever the set button is pressed. if two threshold indicators are on, the threshold will be set to the middle value between the values corresponding to these indicators. press for 0.5 to 2.5 s 3. set the mode selector to run. b. auto-tuning (automatic sensitivity com- pensation) 1. set the mode selector to teach. press the set button once without a sensing object in the sensing area. be sure that all the threshold indicators (red) are on. the built-in buzzer beeps once when the threshold indicators are on. press for 0.5 to 2.5 s 2. set the mode selector to adj and press the set button for three seconds minimum. be sure that the threshold indicator (red) flashes. the built-in buzzer beeps continuously . press for 3 s min. (2) (1) 3. set the mode selector to run. the threshold indicator (red) will continue to flash while the the auto-tuning function is enabled.
e3x-nh e3x-nh 20 threshold setting and indicators at sensitivity setting threshold indicators level 1 2 3 4 5 6 7 8 9 10 11 12 13 maximum sensitivity setting ? use the through-beam sensor for detection of opaque objects. ? use the reflective sensor for detection of objects with no background objects. the threshold will be set to a level slightly higher than the no-light received by the e3x-nh if the sensitivity is set to maximum for the detection of objects that completely interrupt light or the incident of the sensor is very low. reflective sensor the number of lit indicators of the incident level indicators will depend on the incident. the bottom indicator of the threshold indica - tors is on. large small light sensing object threshold incident level indicator threshold indicator sensing object with/without-object teaching ? ideal for the detection of object surface irregularities or minute objects. ? ideal for the detection of objects with background objects reflecting light irregularly . 1. with/without-object t eaching reflective sensor: small light fiber head sensing object large press the set button with the sensing object in the sensing area. set the threshold to the middle value between the values obtained with and without the sensing object. small light fiber head large press the set button with- out sensing object in the sensing area. small light large threshold 2. run/adj mode reflective sensor: the number of lit indicators of the incident level indicators de - pends on the incident. at the time of manual-tuning, it is pos - sible to adjust the threshold in six levels. the default thresh - old is set to 7. large small light sensing object threshold incident level indicator threshold indicator
e3x-nh e3x-nh 21 positioning/no-object teaching ? ideal if it is impossible to perform teaching with the sensing object stationary in the sensing area. ? ideal for high-precision positioning. ? ideal for teaching with only background objects for the detection of bright or dark objects. reflective (light-on) fiber unit 1. press the set button without sensing object in the sensing area. tentatively set the threshold to the value that is 6% of the in - cident level. 6% incident level without background object or sensing object. 6% large small light threshold threshold note: if the incident is low at the time of teaching and the threshold cannot be set to the position corresponding to -6% of the incident level, the sensitivity will be set to maximum auto- matically when the e3x-nh is in run mode. 2. detecting the first object in run/adj mode. tuning range 6% 18% 18% incident level indicator threshold indicator large small light threshold sensing object the photoelec- tric sensor works in reflec- tive operation because the in- cident in- creases. the number of lit indicators of the inci- dent level indicators depends on the inci- dent. the threshold is set to 7. through-beam (dark-on) fiber unit 1. press the set button without sensing object in the sensing area. tentatively set the threshold to the value that is 6% of the in - cident level. 6% 6% large small light threshold threshold incident level without background object or sensing object. note: if the incident is low at the time of teaching and the threshold cannot be set to the position corresponding to -6% of the incident level, the sensitivity will be set to maximum auto- matically when the e3x-nh is in run mode. 2. detecting the first object in run/adj mode. 6% 18% 18% large small light threshold incident level indicator threshold indicator sensing object the photoelectric sensor works in through-beam operation because the inci- dent decreases. the number of lit indicators of the inci- dent level indicators depends on the inci- dent. the threshold is set to 7. tuning range threshold vs. indicators after auto-tuning setting 1. set the initial threshold by performing positioning/no-object teaching in teach mode. 2. press the set button for three seconds minimum in adj mode. initial threshold for auto-tuning tuning range 18% 18% incident level indicator threshold indicator large small light threshold the number of lit indicators of the incident level indicators depends on the incident. the threshold is set to 7. taking into consideration the vibration of the sensing objects on the in-line operation, sample the incident with the first five sens ing ob - jects after setting the threshold and set the threshold again to the middle value between the highest and lowest incident values obt ained with the sensing objects. the e3x-nh will then perform auto-tuning within a range of 18% of this value.
e3x-nh e3x-nh 22 3. with sensing objects passing. the threshold is automatically compensated within the tuning area that has been preset. when the threshold is automatically compen - sated, the threshold indicator will be flash according to the adjusted value. threshold compensation time *t the threshold is compensated 1, 3, 6, 10, 15, 22, and 30 minutes after the e3x-nh/nhb is turned on. after that, the threshold is compensated every 30-minute period. threshold indicator large small light *t note: 1. the alarm signal is output if the threshold compensation range is not within the tuning range. 2. perform sensitivity setting again if the alarm signal is output. dimensions note: all units are in millimeters unless otherwise indicated. amplifier e3x-nh  1 e3x-nhb11 cord: polyvinyl chloride-covered cord 4-mm dia. (18/0.12 dia), 4 cores standard length: 2 m weight: approx. 100 g operation indicator threshold indicators (a) (see note) note: the mounting bracket can be attached to this side. incident level indicators two, 2.4 dia. two, 3.2-dia. holes mounting bracket two, mounting holes
e3x-nh e3x-nh 23 fiber units through-beam (sold in pairs) indicates models that allow free cutting. models without this mark do not allow free cutting. e32-t11l e32-t12l e32-t21l e32-t22l e32-tc200 e32-tc200b e32-tc200b4 e32-t22 e32-tc200e e32-tc200f e32-tc200f4 e32-tc200a note: the value in the parentheses is for the e32-tc200b4. e32-t11r two toothed washers two hexagon clamping nuts sensing head m4 (nickel-plated brass) optical fiber, 2.2 dia. 151-0.075 dia. two toothed washers (for m4) two hexagon clamping nuts (t = 2.4) sensing head (nickel-plated brass) m4 x 0.7 1.4 dia. optical fiber, 2.2 dia. 1.4 dia. 2.4 dia. sensing head (nickel-plated brass) 3 dia. optical fiber, 2.2 dia. two toothed washers 0.9 dia. sensing head m3 x 0.5 (nickel-plated brass) fiber attachment (e39-f9) two hexagon clamping nuts optical fiber, 1 dia. 0.9 dia. 1.8 dia. sensing head, 2 dia. (stainless) heat-shrinkable tubing optical fiber, 1 dia. fiber attachment (e39-f9) two toothed washers two hexagon clamping nuts sensing head m4 x 0.7 (nickel-plated brass) optical fiber, 2.2 dia. 1.0 dia. 1.0 dia. stainless tube (sus304) 1.2 dia max. two hexagon clamping nuts two toothed washers sensing head m4 x 0.7 (nickel-plated brass) optical fiber, 2.2 dia. (see note) 2 dia. fiber attachment (e39-f9) 0.5 dia. sensing head sus303 1.4 dia. heat-shrinking tubing optical fiber , 1 dia. 0.5 dia. optical fiber, 1 dia. sensing head m3 x 0.5 (nickel-plated brass) fiber attachment (e39-f9) two toothed washers two hexagon clamping nuts note: the value in the parentheses is for the e32-tc200f4. 0.5 dia. 0.9 dia. min. stainless tube (sus304) optical fiber, 1 dia. sensing head m3 x 0.5 (nickel-plated brass) two toothed washers two hexagon clamping nuts fiber attachment (e39-f9) (see note) 1.0 dia. 2.6 dia. two toothed washers two hexagon clamping nuts sensing head m3 x 0.5 (nickel-plated brass) optical fiber, 2.2 dia. 3 dia.
e3x-nh e3x-nh 24 e32-t21 e32-t14l e32-t24 e32-t14 optical axis two, 3.2 dia. optical fiber, 2.2 dia. 10-mm-dia. lens (pmma) sensing head (abs) m14 x 1 two hexagon clamping nuts optical fiber, 2.2 dia. e32-t17l e32-t12f 4-mm- dia. lens sensing head, 5 dia. fluoride resin 4 dia. optical fiber, 2.2 dia. four, 0.25 dia. optical fiber , 1 dia. fiber attachment (e39-f9) two toothed washers two hexagon clamping nuts protective tube sensing head (nickel-plated brass) m3 x 0.5 sensing head 1 dia. sus304 2 dia. 1.4 dia. optical fiber, 1 dia. heat-shrinking tubing fiber attachment (e39-f9) lens unit (pmma) 4.4 dia. heat resistive abs 3 dia. sensing head, 3 dia. (stainless) heat-shrinking tubing optical fiber, 2.2 dia. sensing surface nitrile rubber e32-t14f sensing head, 5 dia. fluoride resin 4 dia. optical fiber, 2.2 dia. optical axis e32-t21r e32-t11 sixteen, 0.265 dia. m2.6 x 0.45 sensing head (nickel-plated brass) m4 x 0.7 two toothed washers two hexagon clamping nuts protective tube optical fiber, 2.2 dia. two toothed washers two hexagon clamping nuts sensing head m3 (nickel-plated brass) optical fiber, 2.2 dia. 151-0.037 dia. 3 dia.
e3x-nh e3x-nh 25 e32-t16 mounting holes 0.5-mm w ide slit seal (supplied with the unit in pairs) 1-mm w ide slit seal (supplied with the unit in pairs) 6 dia. two, m3 fiber 2.2 dia. mounting bracket e39-l4 two, 3.2 dia. lens (2 x 10) (pmma) black sensing head (heat-resistive abs) e32-t16p 0.5-mm-wide slit seal (supplied with the unit in pairs) 1-mm-wide slit seal (supplied with the unit in pairs) e32-t16p with e39-l94 (sold separately) mounting two, 3.2 dia., 6-dia. counter sinking sensing head (heat-resistive abs) optical fiber 2.2-dia. sensing surface (2 x 1 1) (pmma) two, m3 sensing head 2.2-dia. fiber e39-l94 mounting bracket (sold separately) black black black
e3x-nh e3x-nh 26 e32-t51 e32-t61 note: section a resists 300 c and section b (which is inserted to the amplifier) resists 1 10 c. the operating temperature of the section to be inserted (marked with *) must be within the operating temperature range of the amplifier . two toothed washers two hexagon clamping nuts sensing head m4 x 0.7 (nickel-plated brass) optical fiber , 2.2 dia. 2.85 dia. 1.5 dia. 4 dia. 4 dia. 5 dia. 2.8 dia. sleeve sus flexible tube hexagon clamping screw 1.0 dia. two hexagon clamping nuts two toothed washers sensing head m4 x 0.7 (sus303) note: resistant temperature is 150 c. resistant temperature is 130 c when used continuously . e32-m21 sensing head m3 x 0.35 (sus303) two hexagon clamping nuts t wo toothed washers silicone tube (see note) plastic fibers, four , 1 dia. sleeve note: one set of silicone tubes is black while the other set is grey for easy identification when they are connected to the emitter and receiver . e32-t54 note: resistant temperature is 150 c. resistant temperature is 130 c when used continuously . sensing head (stainless) optical fiber, 2.2 dia. 3 dia. sensing surface 2 dia. e32-t84s note: section a resists 200 c and section b (which is inserted to the amplifier) resists 1 10 c. the operating temperature of the section to be inserted (marked with *) must be within the operating temperature range of the amplifier . 2.9-dia flexible tube (stainless) sensing head (stainless) lens (2 dia.) sleeve 5 dia. 4 dia. 3 dia. 4 dia. 3 dia. 3.5 dia. 2,000 (standard length) (see note) (see note)
e3x-nh e3x-nh 27 reflective indicates models that allow free cutting. models without this mark do not allow free cutting. e32-d11l e32-d21l two toothed washers two hexagon clamping nuts sensing head (nickel-plated brass) m6 x 0.75 two optical fiber,2.2 dia. 4 dia. two, 1.4 dia. e32-d12 3 dia. two, 1 dia. heat-shrinking tubing optical fibers, two, 2.2 dia. sensing head (stainless) two hexagon clamping nuts two toothed washers sensing head m4 x 0.7 (nickel-plated brass) two fiber attachments (e39-f9) two, 0.9 dia. optical fiber , two, 1 dia. e32-dc200b e32-dc200b4 e32-dc200e two, 1.0 dia. 2.5 dia. max. stainless tube (sus304) two toothed washers two hexagon clamping nuts sensing head m6 x 0.75 (nickel-plated brass) optical fiber,2.2 dia. sensing head m3 x 0.5 (sus304) two hexagon clamping nuts t wo toothed washers two fiber attachments (e39-f9) optical fiber , two, 1 dia. two, 0.5 dia. note: the value in the parentheses is for the e32-dc200b4. e32-d22l two, 0.9 dia. 2.7 dia. sensing head 3 dia. (nickel-plated brass) optical fiber , two, 1 dia. two fiber attachments (e39-f9) e32-dc200 two, 1.0 dia. 4 dia. two toothed washers two hexagon clamping nuts sensing head m6 x 0.75 (adc) optical fiber,2.2 dia. 2,000 (standard length) (see note)
e3x-nh e3x-nh 28 e32-dc200f e32-dc200f4 e32-d11 sixteen, 0.265 dia. sensing head (sus303) m6 x 0.75 two toothed washers two hexagon clamping nuts protective tube optical fiber, two, 2.2 dia. two, 0.5 dia. (see note) note: the value in the parentheses is for the e32-dc200f4. 1.2 dia. max. stainless tube (sus304) sensing head m3 x 0.5 (sus304) two hexagon clamping nuts t wo toothed washers optical fiber, two, 1 dia. two, fiber attachment (e39-f9) four, 0.25 dia. optical fiber , two, 1 dia. two, fiber attachment (e39-f9) two toothed washers two hexagon clamping nuts protective tube sensing head (nickel-plated brass) m3 x 0.5 e32-d21 e32-d33 two, 0.25 dia. 0.8 dia. sensing head (sus303) 3 dia. heat-shrinking tubing optical fiber , two, 1 dia. two, fiber attachment (e39-f9) e32-cc200 note: the fiber for the emitter is identified by a white line. 1.0 dia. for light emission 2.5 dia. two toothed washers two hexagon clamping nuts sensing head m6 x 0.75 (nickel-plated brass) optical fiber, two, 2.2 dia. sixteen, 0.25 dia. for light reception e32-d11r e32-d21r two, 151-0.075 dia. 4 dia. sensing head m6 (adc) t wo, 151-0.037 dia. sensing head m3 (nickel-plated brass) two toothed washers two hexagon clamping nuts optical fiber, two, 2.2 dia. two, fiber attachment (e39-f9) optical fiber , two, 1.0 dia. t wo toothed washers two hexagon clamping nuts e32-d32 note: the fiber for the emitter is identified by a white line. light emission fiber (0.5 dia.) sensing head (sus303) heat-shrinking tubing optical fibers, two, 1 dia. two fiber attachments (e39-f9) light reception fiber (four, 0.25 dia.) 2 dia. 3 dia.
e3x-nh e3x-nh 29 e32-d32l sensing head, 3 dia. (stainless) branching box, 6 dia. (heat-resistive abs black resin) light emission fiber (1 dia.) light reception fiber (sixteen, 0.265 dia.) optical fibers, two, 2.2 dia. note: the fiber for the emitter is identified by a yellow dotted line. e32-d24 light baf fle sensing surface sensing head (sus304) 2 dia. 3 dia. heat-shrinking tubing optical fibers, two, 1 dia. two fiber attachments (e39-f9) e32-d14l 6 dia. sensing head (stainless) heat-shrinking tubing optical fiber, two, 2.2 dia. sensing surface light baffle e32-d12f sensing head, 6 dia. fluoride resin 5 dia. optical fiber, two, 2.2 dia. e32-d51 two, 1.5 dia. two toothed washers two hexagon clamping nuts sensing head,m6 x 0.75* optical fiber, two, 2.2 dia. note: resistant temperature is 150 c. resistant temperature is 130 c when used continuously . *nickel-plated brass e32-d61 note: section a resists 300 c and section b (which is inserted to the amplifier) resists 1 10 c. the operat - ing temperature of the section to be inserted (marked with *) must be within the operating tempera - ture range of the amplifier . 1.4 dia. m4 x 0.7 3.5 dia. 5 dia. sus303 two hexagon clamping nuts two toothed washers sensing head (sus303) m6 x 0.75 sus flexible tube hexagon clamping screw sleeve (see note) 5 dia.
e3x-nh e3x-nh 30 e32-r21 (one e39-r3 re - flector is supplied with the sensor .) e32-d73 note: section a resists 400 c, section b resists 300 c, and section c (which is inserted to the amplifier) resists 1 10 c. the operating temperature of the section to be inserted (marked with *) must be within the operating temperature range of the amplifier . 1.0 dia. sus303 two hexagon clamping nuts two toothed washers sensing head 1.25 dia. sus flexible tube hexagon clamping screw sleeve 1.65 dia. 2.5 dia. 4 dia. 2.8 dia. 5 dia. m4 x 0.7 (sus303) (see note) lens (pmma) silicone tube optical fibers, two, 1 dia. two fiber attachments (e39-f9) sensing head (abs) two hexagon clamping nuts two washers m6 x 0.75 5 dia. e32-r16 (one e39-r1 reflector is supplied with the sensor .) lens (pmma) mounting bracket (attachment) two, m3 screws (attachment) optical fiber, two, 2.2 dia. standard length: 2 m sensing head (abs) e32-l25 e32-l25a note: the fiber for the emitter is identified by a white line. optical fiber, two, 2.2 dia. two, 3.2 dia., 6 dia. spot facing two, 3.2 dia., 6 dia. spot facing optical fiber, two, 2.2 dia. sensing head (heat resistive abs) sensing head (heat resistive abs) sensing distance sensing distance
e3x-nh e3x-nh 31 e32-l25l sensing head (pc) 6 dia. counter sinking optical fiber two, 1-dia. t wo fiber attachment (e39-f9) optical axis sensing head (pc) 6 dia. counter sinking side view prism (pc) optical fiber two, 1-dia. e32-l24l sensing distance lens, two, 3.2 dia. lens, two, 3.2 dia. t wo, 3.2 t wo, 3.2 two fiber attachment (e39-f9) fine through-beam indicates models that allow free cutting. models without this mark do not allow free cutting. e32-t22s 3.5 dia. 2 dia. sensing head (nickel-plated brass) optical fiber 2.2 dia. mounting bracket (attachment) sensing surface e32-t24s 1.7 dia. 3 dia. sensing head (nickel-plated brass) optical fiber 2.2-dia.
e3x-nh e3x-nh 32 slot sensor e32-g14 mounting holes two, m3 sensing head (abs) lens (pmma) optical axis optical fiber, two, 2.2 dia. liquid level fiber units fluid-contact model e32d82f1 f32d82f2 tube-mounting model e32-l25t 6-dia. sensing head (teflon) not bendable: 150 (350)* 9-dia. fiber connector (nickel plated brass) optical fiber , two, 2.2 dia.** 8 dia. to amplifier mounting hole two 3.2-dia lens (pc) sensing head (pc) 2,000 (standard length) two fiber attachments optical fiber, two, 1 dia. *: v alues in parentheses indicate dimensions for the e32-d82f2. **: the optical fiber on the amplifier side (2m) is a plastic fiber and can be freely cut. optical axis reflector reflector (miniature) e39-r3 (supplied with e32-r21) reflector e39-r1 (supplied with e32-r16) note: mounting bracket is attached. adhesive tape two, m3 two, 3.5 dia.
e3x-nh e3x-nh 33 attachments e39-f1 long-distance lens unit e39-f3 lens-equipped reflective unit note: one set includes two units. e39-f2 side-view unit e39-f5 side-view reflective unit e39-f3a small spot lens unit 4 dia. m2.6 effective depth: 3.2 spot facing depth: 0.9 2.8 dia. m2 x 2 4 dia. 6 dia. lens (3.7 dia.) 2.1 dia. note: when mounting, remove all of the accompanying screws first and then screw the e32-tc200a into the e39-f5 until the stopper comes into contact. note: one set includes two units. 4 dia. m2.6 x 0.45 effective depth: 3.8 spot facing depth: 0.9 sensing hole two, 3.2 dia. two, m3 fiber unit mounting holes (e32-tc200a) two, 3.2 dia. mounting hole two, 4 dia. m3 toothed washers two, 3.2 dia. m3 x 6 angle fixing screw two, m3 x 3 slotted head machine screw e39-f1 lens unit installation connection connection with s3d2 sensor controller note: a maximum of two e3x-nh sensors can be connected. +12 v 0 v blue black brown in1 power supply voltage output functions model 100 to 240 v ac relay and, or s3d2-ak and, or, and timer s3d2-ck flip-flop s3d2-bk transistor and, or, and timer s3d2-cc relay 2 inputs, 2 outputs, s3d2-dk 2 inputs, 2 outputs, and timer s3d2-ek 24 vdc and, or s3d2-akd and, or, and timer s3d2-ckd
e3x-nh e3x-nh 34 precautions be sure to heed the following precautions to fully utilize the capabilities of the e3x-nh/nhb. general do not impose any voltage exceeding the rated voltage on the e3x- nh/nhb. do not impose 100 v ac or more on models that operate with dc. in both cases, the e3x-nh/nhb may be damaged. do not short-circuit the load connected to the e3x-nh/nhb, other - wise the e3x-nh/nhb may be damaged. when supplying power to the e3x-nh/nhb, make sure that the po - larity of the power is correct, otherwise the e3x-nh/nhb may be damaged. the load must be connected to the e3x-nh/nhb in operation, otherwise the e3x-nh/nhb may be damaged. fiber unit tightening force the tightening force applied to the fiber unit should be as follows: screw-mounting model cylindrical model spring mounting clip toothed washers nuts (attachment) retaining screw (m 3 max.) clamping torque 3 kgf cm max. fiber units clamping torque m3/m4 screw 0.78 n m (8 kgf cm) m6 screw 0.98 n m (10 kgf cm) 2-mm-dia. column 0.29 n m (3 kgf cm) 3-mm-dia. column 0.29 n m (3 kgf cm) e32-d14l 0.98 n m (10 kgf cm) e32-t12f 0.78 n m (8 kgf cm) e32-d12f 0.78 n m (8 kgf cm) e32-t16 0.49 n m (5 kgf cm) e32-r21 0.59 n m (6 kgf cm) e32-m21 up to 5 mm to the tip: 0.49 n m (5 kgf cm) up to 5 mm from the tip: 0.78 n m (8 kgf cm) e32-l25a 0.78 n m (8 kgf cm) e32-t16p e32-t24s e32-l24l e32-l25l 0.29 n m (3 kgf cm) use a proper-sized spanner . fiber connection and disconnection the e3x-nh/nhb amplifier has a lock button. connect or discon - nect the fibers to or from the e3x-nh/nhb amplifier using the fol - lowing procedures: 1. connection lock button fiber fiber insertion mark remove the protective cover , insert the fiber into the amplifier , and lower the lock button until a click is heard. after cutting the fiber using the e39-f4 fiber cutter , put an insertion mark on the fiber as a guide for correct insertion into the amplifier , and then insert the fiber up to this mark. 2. disconnection remove the protective cover and raise the lock lever to pull off the fiber. (before removing the fiber , be sure to confirm that the lock is released so as to maintain the fiber properties.) protective cover unlocked locked 3. the fiber must be locked or released in a temperature range of 10 c to 40 c.
e3x-nh e3x-nh 35 fiber insertion if the portion from the tip to the insertion mark of the fibers are not inserted into the amplifier unit, the sensing distance will be re- duced. 2.2-mm-dia. fiber thin fiber with the e39-f9 attachment fiber with fixed length 12.6 mm fiber unit amplifier unit insert to the portion from the tip to the insertion mark of each fiber into the amplifier unit. amplifier unit fiber unit 12.6 mm the portion from the tip to the insertion mark of each fiber into the amplifier unit. 12.6 mm amplifier unit the portion from the tip to the insertion mark of each fiber into the amplifier unit. cutting fiber insert a fiber into the fiber cutter and determine the length of the fiber to be cut. press down the fiber cutter in a single stroke to cut the fiber . an insertion mark can be placed on the fiber to serve as a reference when inserting the fiber into the amplifier . use the following proce - dure. confirm through the cutter hole that the fiber is inserted beyond the insertion mark hole so that the insertion mark is properly indicated, and then press firmly down on the cutter . (2) (1) insert the fiber into the amplifier up to the insertion mark. proper fi - ber performance will not be achieved unless the fiber is inserted all the way to the insertion mark. (this method is applicable to stan- dard, 2.2-mm-diameter fibers only .) 12.6 insertion mark 2.2-dia. the cutting holes cannot be used twice. if the same hole is used twice, the cutting face of the fiber will be rough and the sensing dis - tance will be reduced. always use an unused hole. use either one of the two holes on the right (refer to the following figure) to cut a thin fiber as follows: 1. an attachment is temporarily fitted to a thin fiber before shipment. temporarily fitted thin fiber attachment (e39-f9) 2. secure the attachment after adjusting the position of it in the direction indicated by the arrow . 3. insert the fiber into the e39-f4 to cut. three holes for standard fiber (2.2-mm dia.) cutter e39-f4 two holes for thin fiber 4. finished state (proper cutting state) approx. 0.5 mm note: insert the fiber in the direction indicated by the arrow . connection do not pull or press the fiber units. the fiber units have a with- stand force of 9.8 n (1 kgf) or 29.4 n (3 kgf) (pay utmost attention because the fibers are thin). do not bend the fiber units beyond the permissible bending radius. do not bend the edge of the fiber units (excluding the e32-t  r and e32-d  r). correct incorrect 20 mm min. amplifier unit fiber unit 20 mm min.
e3x-nh e3x-nh 36 do not apply excess force on the fiber units. fiber unit nylon wireholder correct incorrect metal holder the fiber head could be break by excessive vibration. t o prevent this, the following is ef fective: a one-turn loop can absorb vibrations. tape bending radius e39-f11 sleeve bender the bending radius of the stainless tube should be as large as pos - sible. the smaller the bending radius becomes, the shorter the sensing distance will be. insert the tip of the stainless tube to the sleeve bender and bend the stainless tube slowly along the curve of the sleeve bender (refer to the figure). fiber tip position mark do not bend here. 1.2 dia. max. 1.3 dia. min. 1.2 dia. max. r 12.5 r 7.5 r 10 r 5 stainless tube 90 o max. 10 10 amplifier units mounting mounting 1. mount the front part on the mounting bracket (attachment) or a din track. 2. press the back part onto the mounting bracket or the din track. note: do not mount the back part onto the mounting bracket or the din track first and then mount the front part on the mounting bracket or the din track, or the mounting strength of the amplifier unit may decrease. (1) (2) din track dismounting by pressing the amplifier unit in direction (3) and lifting the fiber in - sertion part in direction a4o as shown in the following, the amplifier can be dismounted with ease. (4) (3) din track in the case of side mounting, attach the mounting bracket on the amplifier first, and secure the amplifier with m3 screws and wash - ers. the diameter of the washers should be 6 mm max. washers (6 dia. max.)
e3x-nh e3x-nh 37 turning the power on after the e3x-nh/nhb is turned on, the e3x-nh/nhb will be ready to operate in 100 ms maximum. if power is supplied to the e3x-nh and the load is connected to the e3x-nh/nhb independently, be sure to turn on the power supply connected to the e3x-nh/nhb first. when the power is turned on, the operation indicator will be on momentarily. note that this will not have an effect on performance since no control output will be generated. mutual interference protection function perform two-point teaching if two to three fiber units are closely mounted together, at which time supply power only to the unit in teaching operation in turn or block the emitters of the fiber units not in teaching operation. eeprom writing error write errors may result at the time of teaching due to power failure or static noise, in which case the unit beeps and the operation indica - tors flash. if any of these occur , re-input teaching using the teaching button on the amplifier . minute sensing object this datasheet shows typical examples for detecting minute ob- jects. these typical examples are for reference use only , because these example operations were tested on units sampled at random from a lot and the values described are average values. do not assume that all units ensure such operations. others when the power is off: the moment power is turned off , the e3x-nh/nhb may output a pulse signal which could affect the operation of the devices con- nected to it. this will occur more often if power is supplied to the e3x-nh from an external power supply, thus affecting the con- nected timer and counter . use a built-in power supply as much as possible to avoid this. in a case where the cord is extended, use a wire with 0.3 mm 2 min. the total length of the cord should be 100 m max. power supply: if a standard switching regulator is used as a power supply, the frame ground (fg) terminal and the ground (g) terminal must be grounded, or otherwise the e3x-nh can malfunction influenced by the switching noise of the power supply . the supplied voltage must be within the rated voltage range. unreg - ulated full- or half-wave rectifiers must not be used as power sup- plies. do not lay wiring to the optical sensor together with power lines in the same piping or ducts. doing so will cause induction between the lines, possibly resulting in faulty operation or destruction. always lay wiring to the optical sensor in separate or dedicated piping. power line attachment units applications e39-f10 fiber connector use the following procedure (refer to the figure) to connect fibers via the fiber connector . splice retention unit retention unit fiber unit each fiber unit should be as close as possible before they are con - nected. sensing distance will be reduced by approximately 25% when fibers are connected. only fibers with a 2.2-mm dia. can be connected. (refer to page 9 for applicable fiber units.) protective spiral t ube insert a fiber to the protective spiral t ube from the head connector side (screwed) of the tube. fiber unit protective spiral tube push the fiber into the protective spiral tube. the tube should be straight so that the fiber is not twisted when inserted. then turn the end cap of the spiral tube. protective spiral tube fiber unit secure the protective spiral tube on a suitable place with the at- tached nut. mounting panel hexagon clamping nut fiber unit toothed washer protective spiral tube
e3x-nh e3x-nh 38 use the attached saddle to secure the end cap of the protective spi - ral tube. to secure the protective spiral tube at a position other than the end cap, apply tape to the tube so that the portion becomes thicker in diameter . saddle end cap tube warning the e3x-nh/nhb is not a safety component for ensuring the safety of people as defined in ec directive 91/368/eec, or as covered by separate european standards or by any other reg - ulations or standards. reflector observe the following precautions when using the reflec - tor (e39-r3) use detergent, etc., to remove any dust or oil from the surfaces where tape is applied. adhesive tape will not be attached properly if oil or dust remains on the surface. the e39-r3 cannot be used in places where it is exposed to oil or chemicals. !
e3x-nh e3x-nh 39
e3x-nh e3x-nh 40 all dimensions shown are in millimeters. to convert millimeters into inches, multiply by 0.03937. t o convert grams into ounces, multiply by 0.03527. cat. no. e258-e1-3 in the interest of product improvement, specifications are subject to change without notice. printed in japan 0698-1.5m (0297) a omron corporation industrial sensors division sensing devices and components division h.q. 28th fl., crystal t ower bldg. 1-2-27, shiromi, chuo-ku, osaka 540-6028 japan phone: (81)6-949-6012 fax: (81)6-949-6021


▲Up To Search▲   

 
Price & Availability of E3X-NH41

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X